AutonoMe®
Delivery System
The ultimate experience of control at every step1
AutonoMe® Delivery System
The ultimate experience of control at every step1
AutonoMe® is the First-of-its-kind automated, disposable, pre-loaded IOL delivery system.
Intuitive Control for a Smooth IOL Delivery1-3
68% of surgeons found the delivery speed easy to control2*
The responsive speed control lever2
- Provides full control of plunger advancement
- Allows surgeons to precisely start, stop and linearly adjust speed at any time during surgery
- Helps surgeons focus more on the patient
70% of surgeons rated the overall experience of AutonoMe® as smooth and effortless2†
An excellent delivery mechanism2,3
- Smooth, automated IOL delivery of up to 3 mm/sec
- Steady and continual motion providing a new level of control over IOL delivery speed
*Ease of controlling plunger advancement during IOL delivery; percent of total participants (n=136) from US, EU, Brazil & Japan. Study was conducted with porcine cadaver eyes (6 eyes per participant with over 800 eyes in total).
†Surgeons most commonly answered “Smooth” (43%) and “Effortless” (27%). Percent of total participants n=136 participants from US, EU, Brazil & Japan. Study was conducted with porcine cadaver eyes (6 eyes per participant with over 800 eyes in total).
Designed to fit comfortably in surgeons’ hands for intuitive single-handed control of the device1-3
- Designed for a natural fit to suit multiple surgical techniques, with no injection force required
- Single-handed design frees the second hand for globe stabilisation
- Precise control of nozzle tip orientation allows for consistent delivery of the IOL into the capsular bag
Designed to fit comfortably in surgeons’ hands for intuitive single-handed control of the device1-3
- Designed for a natural fit to suit multiple surgical techniques, with no injection force required
- Single-handed design frees the second hand for globe stabilisation
- Precise control of nozzle tip orientation allows for consistent delivery of the IOL into the capsular bag
Preserves Wound Integrity4*
AutonoMe® features a proprietary depth guard1,4
- Allows reduced stress and damage to the surrounding tissue
- Control of nozzle insertion depth
- Minimised incision enlargement*
- Greater resistance to nozzle tip splitting
- Precise delivery into the capsular bag
*Ex-vivo, exploratory laboratory study performed on 32 human cadaver eyes.
The AutonoMe® nozzle tip is designed to maintain wound integrity by5*
- Preserving corneal tissue
- Minimising damage to Descemet’s membrane
*Study conducted on 32 human cadaver eyes that were randomly assigned to receive IOLs implanted with the preloaded delivery devices.
†Trademarks are the property of their respective owners
AutonoMe® demonstrates low incidence of Descemet’s membrane detachment, compared to other delivery systems5
Easier to Use than Competitor Devices
AutonoMe® is reported to be easier to use compared to iTxx and iSxxx2†
AutonoMe® is ready to use in 3 simple steps1
AutonoMe® is Pre-Loaded with Clareon® IOL
Clareon® IOL offers outstanding refractive outcomes and excellent clarity that lasts.6-14
AutonoMe® is Pre-Loaded with Clareon® IOL
Clareon® IOL offers outstanding refractive outcomes and excellent clarity that lasts.6-14
Hear From an Expert
Hear what surgeons are saying about AutonoMe® Delivery System.
PLACEHOLDER
PLACEHOLDER
PLACEHOLDER
AutonoMe Clinical Studies
Technical Specifications1
*Please refer to relevant product IFU for qualified combinations of cartridges and their use with Clareon® family of IOLs in Monofocal, Toric, PanOptix®, PanOptix® Toric, and Vivity®
Instructions for Use (IFU)
For a full list of indications, contraindications and warnings, please visit ifu.alcon.com and refer to the relevant product’s instructions for use.
Alcon Experience Academy
For relevant training content from industry thought leaders
References:
1. Clareon® AutonoMe® Directions for Use.
2. Nozzle Preference and Delivery System Performance Study between AutonoMe and UltraSert V3.5 - TDOC 0053876.
3. Verification Report, IOL Inserter Plunger Speed Testing. Alcon internal document REF-04194.
4. Liu J, Wolfe P, Hernandez V, Kohnen T. Comparative assessment of the corneal incision enlargement of 4 preloaded IOL delivery systems. J Cataract Refract Surg. 2020 Jul;46(7):1041-1046.
5. Alcon Data on File. TDOC-0054429.
6. Werner L, Thatthamla I, Ong M, et al. Evaluation of clarity characteristics in a new hydrophobic acrylic IOL. J Cataract Refract Surg. 2019;45:1490-1497.
7. Clareon® IOL Directions for Use.
8. Alcon Data on File, 2017. [TDOC-0050244].
9. Alcon Data on File, 2017. [TDOC-0054028].
10. Alcon Data on File, 2017. [TDOC-0053564].
11. Alcon Data on File, 2017. [TDOC-0053584].
12. Alcon Data on File, 2020. [TDOC-0057291].
13. Stanojcic N, O’Brart D, Hull C, et al. Visual and refractive outcomes and glistenings occurrence after implantation of 2 hydrophobic acrylic aspheric monofocal IOLs. J Cataract Refract Surg. 2020;46(7):986-994.
14. Oshika T, Fujita Y, Inamura M, Miyata K. Mid-term and long-term clinical assessments of a new 1-piece hydrophobic acrylic IOL with hydroxyethyl methacrylate. J Cataract Refract Surg. 2020;46(5):682-687.
Please refer to the relevant product direction for use for list of indications, contraindications and warnings.
GC571081050118
Registered under Act 737
The content is intended for Healthcare Professionals only, not for general public