長期に渡る良好な遠方視1-5
Clareon® IOLは良好な遠方視力を維持しながら実用的な中間視力を実現します6-9
長期に渡る良好な遠方視1-5
Clareon® IOLは良好な遠方視力を維持しながら実用的な中間視力を実現します6-9
Clareon®は高い透明性と予測可能な屈折安定性を提供します1-3, 10, 11†
- 実用的な中間視力によるQOVの向上3, 12, 13
- 良好な屈折安定性3, 5, 14
- 透明性の追求10†
†Among the lowest levels of surface haze, SSNGs, and glistenings of competitive IOLs.
‡Trademarks are the property of their respective owners.
実用的な中間視力による良好なQOV3,6-8,12,13,15
Clareon® IOLは良好な遠方視力 (20/20) を維持しながら実用的な中間視力 (60cm中間で20/32) を実現します6-8,15,*†
*Based on two Vivity® registration studies, which used SN60WF as the control, AcrySof® IQ monofocal IOLs provided mean binocular distance corrected intermediate VA at 0.2 logMAR
†Based on Studies with AcrySof®; Clareon® and AcrySof® are optically equivalent with the same -0.2µm aspheric design resulting in improved depth of focus.
UCIVA = Uncorrected Intermediate Visual Acuity DCIVA = Distance Corrected Intermediate Visual Acuity OUS = Outside United States
Clareon®独自の精密なエッジデザインによるエッジグレアを軽減します3,12,13
Clareon® IOLの精密なエッジデザイン
他社IOL
グレアシュミレーションにより日常生活にグレアがもたらす影響を可視化します
Clareon®は光学部 6mm全てを有効的に利用できます3, 12, 13
Clareon®
有効光学径6mm
他社A
有効光学径4.9mm
他社B
有効光学径4.9mm
Images were captured using a Keyence video microscope under precisely controlled conditions. Each IOL (+25.0 D) was placed into a wet cell model eye containing BSS® and a spherical aberration neutral simulated cornea. For each IOL, the target image was captured using the identical test conditions and camera settings without additional focusing. All elements (the Keyence microscope, the IOL in wet cell, the model cornea, and the target image) were located in exactly the same place using the exact same imaging settings on the Keyence in the manual mode. Optics are presented in black and white for illustrative purposes only.
*Trademarks are the property of their respective owners.
Clareon®:PCO抑制による長期に渡る良好な視機能3,16
PCO抑制効果:YAG施行率を最小限に
良好な屈折安定性3-5, 14
STABLEFORCEは®他のIOLと比較して良好な屈折安定性を提供します3-5, 14†
様々な嚢サイズに対して良好な屈折安定性4
Clareon®は様々な嚢サイズに対して確実な中心固定を提供します3-5, 14
STABLEFORCE®は良好な中心固定を提供します3-5, 14
For illustrative purposes only.
†Trademarks are the property of their respective owners.
透明性を追求するための進化した
製造プロセス2, 10, 18, 19
Clareon®では長期に渡りグリスニングは観察されませんでした2, 11
Clareon® IOLでは術後3年と9年の長期臨床試験においてグリスニングが観察されませんでした2, 11*†
*Defined as Miyata grade 0, <25mv/mm2 over 3 years (n=138), and over 9 years (n=20), respectively.
‡Trademarks are the property of their respective owners.
他社IOLと比較してグリスニングが少ないことが示されました10
†Trademarks are the property of their respective owners.
‡Denotes statistical significance for comparison of slit lamp surface haze as determined by a one-way ANOVA (P<0.001) compared with Clareon®.
透明性と優れた軸安定性5,10,13,20,21
AlconオンラインTORICカリキュレーター
Clareon®のためにデザインされたマニュアルとプリロードデリバリーデバイス
Please contact your local Alcon representative for IOL
delivery systems available in your market.
Clareon®のためにデザインされたマニュアルとプリロードデリバリーデバイス
Please contact your local Alcon representative for IOL delivery systems available in your market.
Clareon® and Clareon® Toric Clinical Studies
製品仕様
†Blue Light + UV Filter
‡UV Filter Only
*Based on an average pseudophakic human eye using an SRK/T optical A-constant of 119.1
†Blue Light + UV Filter
‡UV Filter Only
Alcon Experience Academy
眼科医療関係者向けの豊富なビデオライブラリー
References:
1. Lehmann R, Maxwell A, Lubeck DM, Fong R, Walters TR, Fakadej A. Effectiveness and Safety of the Clareon Monofocal Intraocular Lens: Outcomes from a 12-Month Single-Arm Clinical Study in a Large Sample. Clin Ophthalmol. 2021;15:1647-1657. Published 2021 Apr 20. doi:10.2147/OPTH.S295008
2. Oshika T, Fujita Y, Inamura M, Miyata K. Mid-term and long-term clinical assessments of a new 1-piece hydrophobic acrylic IOL with hydroxyethyl methacrylate. J Cataract Refract Surg. 2020;46(5):682-687.
3. Clareon® IOL Directions for Use.
4. Lane, S, Collins, S, Das, K et al. Evaluation of intraocular lens mechanical stability. J Cataract Refract Surg. 2019;45(4):501-506.
5. Alcon Data on File, 2017. [TDOC-0054028]
6. AcrySof® IQ Vivity™ IOL Directions for Use
7. Bala C, Poyales F, Guarro M, Mesa RR, Mearza A, Varma DK, Jasti S, Lemp-Hull J. Multi-country clinical outcomes of a new nondiffractive presbyopia-correcting intraocular lens. J Cataract Refract Surg. 2021 Jun 11. doi: 10.1097/j.jcrs.0000000000000712. Epub ahead of print. PMID: 34288635.
8. Alcon Data on File, 2021. [A01970-REP-211731]
9. Varma, Devesh, et al. Clinical Outcomes of a New Non-Diffractive Presbyopia-Correcting Intraocular Lens From Two Large Confirmatory Studies. American Academy of Ophthalmology. Abstract: PA005.
10. Werner L, Thatthamla I, Ong M, et al. Evaluation of clarity characteristics in a new hydrophobic acrylic IOL in comparison to commercially available IOLs. J Cataract Refract Surg. 2019;45(10):1490-1497. doi:10.1016/j.jcrs.2019.05.017
11. Maxwell A, Suryakumar R. Long-term effectiveness and safety of a three-piece acrylic hydrophobic intraocular lens modified with hydroxyethyl-methacrylate: an open-label, 3-year follow-up study. Clin Ophthalmol. 2018;12:2031–2037.
12. Alcon Data on File, 2017. [TDOC-0050244]
13. Das KK, Werner L, Collins S, Hong X. In vitro and schematic model eye assessment of glare or positive dysphotopsia-type photic phenomena: Comparison of a new material IOL to other monofocal IOLs. J Cataract Refract Surg. 2019;45(2):219-227.
14. Alcon Data on File, 2017. [TDOC-0053564]
15. Alcon Data on File; TDOC – 055575; 09/Apr/2019
16. AcrySof® IQ IOL Directions for Use
17. Alcon Data on File, 2017. [TDOC-0054422]
18. Alcon Data on File, 2020. [TDOC-0057291]
19. Stanojcic N, O’Brart D, Hull C, et al. Visual and refractive outcomes and glistenings occurrence after implantation of 2 hydrophobic acrylic aspheric monofocal IOLs. J Cataract Refract Surg. 2020;46(7):986-994.
20. Lee BS, Chang DF. Comparison of the rotational stability of two toric intraocular lenses in 1273 consecutive eyes. Ophthalmology. 2018;125(9):1325-1331
21. Clareon® Toric IOL Directions for Use.
22. Alcon Data on File, 2019. [TDOC-0055470]
Please refer to the relevant product direction for use for list of indications, contraindications and warnings. Find at: https://ifu.alcon.com
1. 販売名:Clareon 眼内レンズ AutonoMe オートプリロードデリバリーシステム、医療機器承認番号:23000BZX00234000、一般的名称:挿入器付後房レンズ
2. 販売名:Clareon 非球面 疎水性 アクリル眼内レンズ 、医療機器承認番号:22900BZX00387000、一般的名称:後房レンズ
3. 販売名:Clareon TORIC 眼内レンズ AutonoMe オートプリロードデリバリーシステム、医療機器承認番号:30200BZX00237000、一般的名称:挿入器付後房レンズ
4. 販売名:Clareon TORIC 非球面 疎水性 アクリル眼内レンズ、医療機器承認番号:30200BZX00290000、一般的名称:後房レンズ
5. 販売名:モナーク ハンドピース、医療機器届出番号:13B1X00211000014、一般的名称:眼内レンズ挿入器