The ARGOS®
Biometer

 

Smarter planning starts in the clinic.

ARGOS Biometer on tray table with monitor
Flowchart with icons of ARGOS® Workflow, Smart Planning Solution and Image Guided Integration


Faster.1-5 Easier.5,6* Better.1,2,7,8

 

The ARGOS® Biometer with Image Guidance by Alcon is the smarter planning solution that keeps efficiency and accuracy flowing through your clinic.

 

* Compared to VERION® Reference Unit.

Your Solution For Smarter Planning

The Faster Solution1-5

 

• Measurement capture speed <1.0 sec9‡ 
• 1.5x faster scanning speed than IOLMaster* 7001† 

 

* Trademarks are the property of their respective owners. 
† At 3000 A-Lines/sec as compared to 2000 A-Line/sec for IOLMaster* 700
‡ With capture times as low as 0.6 seconds.

 

Computer screenshot of ARGOS® biometer with Image Guidance by Alcon generating patient eye measurements

The Easier Solution5,6*

 

• Angle-to-angle, cornea-to-retina OCT imaging provides real-time guidance for capturing accurate measurements
• Integrated Alcon Vision Planner with automated and convenient planning software offers sophisticated astigmatic management tools, including an LRI nomogram
• One-touch software and remote planning options

 

* Compared to VERION® Reference Unit.

 

Computer screenshot of ARGOS® biometer and Alcon Vision Planner generating patient measurements

The Better Solution1,2,7,8

 

Advanced SS-OCT technology provided higher acquisition rates than other market-leading biometers1

 

• Outperformed IOLMaster* 700 by 41% in grade 4+ cataracts1
• OCT-enhanced keratometry shown to rival Lenstar*1
• Uses segmented axial length, improving refractive prediction error, which may lead to better IOL selection7,10
 

Graph showing ARGOS® has a 89.9% acquisition rate of grade 4+ cataracts, 41% higher than the IOLMaster* 700 with a 63.6% acquisition rate.

Image Guided Precision Powered By Alcon

 

Experience complete integration for intelligent planning and empowered execution with enhanced precision at every step.

Experience complete integration for intelligent planning: ARGOS® in Clinic, Digital Marker LenSx, Digital Marker Microscope, ORA® with AnalyzOR, NGENUITY®

Image Guided Execution

 

• Reduces the risk of transcription errors11
• Provides intra-operative guidance with digital overlays throughout LenSx® procedures based on Vision Planner data11

• Provides image registration and real time eye tracking to compensate for cyclotorsion. Precisely execute11:

  • Rhexis placement and centration

  • Primary, secondary and arcuate incision

 

Computer screenshot of VERION Image Guided System generating patient measurements

With VERION® Digital Marker LenSx® (DML) integration, surgeons will be able to:

 

• Plan arcuate incision using the nomogram integrated into the Vision Planner or personal nomograms added to the planner software12
• Import surgical plans from the Vision Planner via USB, LAN (Local Area Network) or SMARTCataract to reduce the risk of transcription errors11

• Ensure precision of arcuate location with image-guided registration to the pre-op image11

 

 

Graph showing LenSx® with VERION® planning has a 72% relative change in cylinder power, 16% higher than with LenSx® manual planning.

Integration with the Digital Marker Microscope (DMM) helps you execute your patient’s surgical plan with digital accuracy.14

 

 

Image of Digital Marker Microscope and ARGOS® biometer.

Image Guided Integration from the clinic to the OR designed to increase precision and enhance data integrity.11

The Vision Planner sends the surgical plan to the DMM, eliminating transcription errors and allowing surgeons to precisely execute their plan with image-guided precision11.

At the end of the case, the DMM sends surgical data back to the Vision Planner14:

 

•    Surgery date 
•    Procedure type 
•    Incision width 
•    Final IOL implanted

 

An image of the final IOL position at the end of the case can be captured and stored for future reference.12

 

Computer screenshot of VERION Image Guided System generating patient measurements
Dynamic overlay of the Alcon Vision Planner
Dynamic overlay of the Alcon Vision Planner

 

Dynamic overlays can help to precisely execute incisions14

 

Image-guided integration of the Alcon Vision Planner
Image-guided integration of the Alcon Vision Planner

 

Image-guided integration can help to achieve greater capsulorhexis accuracy15

 

Toric IOLs aligned precisely to planned implantation axis with the Alcon Vision Planner
Toric IOLs aligned precisely to planned implantation axis with the Alcon Vision Planner

 

Precisely align toric IOLs according to your planned implantation axis, mapped to your patient’s unique limbal and iris landmarks14

 

Final IOL position as captured by the Alcon Vision Planner
Final IOL position as captured by the Alcon Vision Planner

 

An image of the final IOL position is captured and stored for future reference12

 

Alcon Experience Academy

 

A non-promotional training and education resource for eye care professionals.
 

 

Get Training & Resources

Alcon Experience Academy

 

A non-promotional training and education resource for eye care professionals.
 

 

Get Training & Resources

ARGOS® Optical Biometer
Caution: Federal law restricts this device to the sale by or on the order of a physician.


Indications: ARGOS® is a non-invasive, non-contact biometer based on swept-source optical coherence tomography (SS-OCT). The device is intended to acquire ocular measurements as well as perform calculations to determine the appropriate intraocular lens (IOL) power and type for implantation during intraocular lens placement.

Intended Use: The Reference Image functionality is intended for use as a preoperative and postoperative image capture tool. It is intended for use by ophthalmologists, physicians, and other eye-care professionals and may only be used under the supervision of a physician.

Warnings and Precautions:
• Only properly trained personnel with experience may operate the device and control software and interpret the results.
• Factors that influence the measurement of patient’s eyes are listed in the User Manual (Table 1): pseudophakic eye, wearing contact lenses, fixation problem, cornea opacity, non-intact cornea, refractive surgery, blood in the vitreous humor, retinal detachment, keratoconus, asteroid hyalosis, ambient light in the room, and deformation of the corneal shape. Please consider the guidance provided in Table 1 when you encounter these factors.
• Optical Radiation - This device is equipped with a Class 1 laser light source.

ATTENTION: Refer to the ARGOS® User Manual for a complete description of proper use and maintenance, optical and technical specifications, as well as a complete list of warnings and precautions.

References
 

1. Tamaoki A, Kojima T, Hasegawa A, et al. Clinical evaluation of a new swept-source optical coherence biometer that uses individual refractive indices to measure axial length in cataract patients. Ophthalmic Res. 2019;19:1-13.
2. Shammas HJ, Ortiz S, Shammas MC, Kim SH, Chong C. Biometry measurements using a new large-coherence-length swept-source optical coherence tomographer. J Cataract Refract Surg. 2016;42:50-61.
3. Hussaindeen JR, Mariam EG, Arunachalam S, et al. Comparison of axial length using a new swept-source optical coherence tomography-based biometer. PLOS ONE. December 2018.
4. ZEISS† IOLMaster† 700 510k Submission 2015.
5. ARGOS® Biometer User Manual 2019.
6. VERION® Reference Unit User Manual, Part I. 2019.
7. Whang W, Yoo Y, Kang M, Joo C. Predictive accuracy of partial coherence interferometry and swept-source optical coherence tomography for intraocular lens power calculation. Sci Rep. 2018;8(1):13732.
8. Shammas HJ. Accuracy of IOL power formulas with true axial length versus simulated axial length measurement in 318 eyes using an OCT biometer. 2019 ASCRS ASOA Annual Meeting. May 2019.
9. Alcon Data on File.
10. Wang L, Cao D, Weikert MP, Koch DD. Calculation of axial length using a single group refractive index versus using different refractive indices for each ocular segment. Ophthalmology. 2019:1-8.
11. VERION® Digital Marker L User Manual. 2017.
12. VERION® Reference Unit User Manual Part II. 2017.
13. Chen M, Seagrave Z, Patrianakos T, et al. A Pilot Study To Compare Using VERION®  Imaging Guided System (Alcon) To Manual Marking In Assisting LRI (Limbal Relaxation Incision) To Reduce Cylinder Power In Cataract Surgery. International Journal of Open Access Ophthalmology. 2016;1(1):1-4.  
14. VERION® Digital Marker M User Manual. 2018.
15. Haeussler-Sinangin Y, Dahlhoff D, Schultz T, Dick HB. Clinical performance in continuous curvilinear capsulorhexis creation supported by a digital image guidance system. J Cataract Refract Surg. 2017;43:348-352.